Cisco ASR 9006 System ASR-9006-DC-V2 ASR 9006 DC Chassis with PEM Version 2

Cisco

Model: ASR-9006-DC-V2 Cisco Router ASR 9006
Detail: Cisco ASR 9006 System ASR-9006-DC-V2 ASR 9006 DC Chassis with PEM Version 2
Brand: CISCO
Condition: Brand New Sealed
Availability: IN STOCK

$29.03

InquiryCompare

ASR-9006-DC-V2 Specification

ASR-9006-DC-V2 Specifications

Description Cisco ASR 9006 System ASR-9006-DC-V2 ASR 9006 DC Chassis with PEM Version 2

Cisco ASR 9006 Specs

Physical specifications Height: 17.50 in. (444.5 mm) (10 RU)

Width: 17.38 in. (441.45 mm)

Depth:

b  With doors: 29.05 in. (737.9 mm)

b  Without doors: 29.05 in. (737.9 mm)

Weight:

b  89.55 lb (40.7 kg) (chassis with PEM)

150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) b RSP, two v2 FAN trays, PEMs

Slot orientation Horizontal
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 4 line-card slots
bCommonsb components 2 RSPs

2 fan trays

1 PEM (either DC or AC)

1 fan filter

Reliability and availability Fabric redundancy

Fan redundancy

Feed redundancy

Power-supply redundancy

RSP redundancy

Software redundancy

Rack mounting 19-in. default

21- and 23-in. adapters available

Note: Minimum 17.75-in. opening between posts is needed for proper operation

Cabinet mounting Yes

Note: Doors not recommended in enclosed cabinets

Wall mounting No
Airflow Right-to-back, Front-to-back with baffle

Performance

Fabric One per RSP:

b  Active/active nonblocking operation mode in dual-RSP redundant configuration

b  Fully redundant in dual-RSP redundant configuration

b  Built-in service-intelligence and traffic-prioritization capability

Thermal Two fan trays:

b  6 high-efficiency fans per tray

b  Variable-speed fans for optimal thermal performance

b  No single point of failure

Power

Modularity Pay-as-you-grow power for future scalability, available in AC and DC.

Multiple power module types:

b  3 kW AC power module

b  2.1 kW DC power module

Note: Mixing of AC and DC modules is not supported

Redundancy b  AC: N+N redundancy

b  DC: N+1 redundancy

b  Power module redundancy

b  A/B Feed redundancy

Power zones No power zone restrictions

Fully load-sharing power infrastructure

Power input Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)

Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)

Power-module airflow Front-to-back

Operating temperature (nominal)

41 to 104B:F (5 to 40B:C)

Operating temperature (short-term)[2]

ASR 9006: 23 to 131B:F (-5 to 55B:C)

ASR 9010: 23 to 122B:F (-5 to 50B:C)

Operating humidity (nominal) (relative humidity)

5 to 90%

Storage temperature

-40 to 158B:F (-40 to 70B:C)

Storage (relative humidity)

5 to 93%

Operating altitude

-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)

Network Equipment Building Standards (NEBS)

Cisco ASR 9006 is designed to meet:

b  SR-3580: NEBS Criteria Levels (Level 3)

b  GR-1089-CORE: NEBS EMC and Safety

b  GR-63-CORE: NEBS Physical Protection

b  VZ.TPR.9205: Verizon TEEER

ETSI standards

Cisco ASR 9006 is designed to meet:

b  EN300 386: Telecommunications Network Equipment (EMC)

b  ETSI 300 019 Storage Class 1.1

b  ETSI 300 019 Transportation Class 2.3

b  ETSI 300 019 Stationary Use Class 3.1

EMC standards emission

Cisco ASR 9006 is designed to meet:

b  FCC Class 47CFR15 A

b  ICES 003 Class A

b  AS/NZS CISRP22 Class A

b  CISPR 22 (EN55022) Class A

b  VCCI Class A

b  BSMI Class A

b  IEC/EN 61000-3-12: Power Line Harmonics

b  IEC/EN 61000-3-11: Voltage Fluctuations and Flicker

b  EN55022: Information Technology Equipment (Emissions)

b  EN 50121-4: Railway EMC

EMC standards immunity

Cisco ASR 9006 is designed to meet:

b  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)

b  IEC/EN-61000-4-3: Radiated Immunity (10V/m)

b  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)

b  IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)

b  IEC/EN-61000-4-5: Signal Surge Ports (1kV)

b  IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)

b  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)

b  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)

b  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations

b  EN55024: Information Technology Equipment (Immunity)

b  EN50082-1/EN-61000-6-1: Generic Immunity Standard

b  EN 50121-4: Railway EMC

Safety

Cisco ASR 9006 is designed to meet:

b  UL/CSA/IEC/EN 60950-1

b  IEC/EN 60825 Laser Safety

b  ACA TS001

b  AS/NZS 60950

b  FDA Code of Federal Regulations Laser Safety

SKU: ASR-9006-DC-V2 Category:
brands

Cisco